Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Laboratory Medicine ; (12): 581-588, 2022.
Artigo em Chinês | WPRIM | ID: wpr-958555

RESUMO

Objective:To establish the biology reference interval (RI) of peripheral blood procalcitonin (PCT) for children between 3 days and 6 years old in China.Methods:Totally 3 353 reference individuals with apparent health or no specific diseases were recruited in 18 hospitals throughout the country during October 2020 to May 2021. Reference individuals were divided into four groups: 3-28 days, 29 days - 1 year, 1-3 years and 4-6 years. Vein blood or capillary blood were collected by percutaneous puncture from every reference individual. The PCT level in serum and the capillary whole blood were assayed by Roche Cobas e601 and Norman NRM411-S7 immunoanalyzer. Outliers were deleted and 95th percentiles of every group were provided as RIs. Man-Whitney U test or Kruskal-Wallis test were used performed to assess the difference among different gender, age or method groups. Results:The difference of PCT distribution between male and female is not statistically significant, but the difference between serum and capillary whole blood is statistically significant. The differences between age groups are significant too. For Roche e601, serum PCT RI of 3-28 days group is <0.23 μg/L, 29 days - 6 years are <0.11 μg/L. For NRM411, Serum PCT RI of 3-28 days group is <0.21 μg/L, 29 days - 1 year: <0.09 μg/L, 1 - 6 years: <0.10 μg/L. For whole blood PCT, RI of 3-28 days group is <0.26 μg/L, 29 days - 6 years is <0.15 μg/L.Conclusions:Serum and capillary whole blood PCT have different RIs, however, capillary whole blood PCT testing is valuable in pediatric application. Children in 3-28 days show higher PCT levels than other age group. To establish the RIs and understand the differences among different groups are essential for the interpretation and clinical application of peripheral blood PCT testing results.

2.
Chinese Journal of Laboratory Medicine ; (12): 633-643, 2021.
Artigo em Chinês | WPRIM | ID: wpr-912453

RESUMO

Objective:To explore the performance of the commonly used whole blood C-reactive protein (CRP) detection systems and give related recommendation on the performance requirements of detection systems.Methods:A total of 7 540 venous blood samples from 26 maternal, child and children′s hospitals were collected to conduct this multi-center study on the analytical performance of 5 commonly used whole blood CRP detection systems from March to April in 2019. The blank check, carryover, repeatability, intermediate precision, linearity, sample stability, influence of hematocrit/triglyceride/bilirubin, comparison with SIEMENS specific protein analyzer and trueness were evaluated. The 5 systems included BC-5390CRP autohematology analyzer, AstepPLUS specific protein analyzer, Ottoman-1000 Automated Specific Protein POCT Workstation, i-CHROMA Immunofluorometer equipment Reader and Orion QuikRead go detecting instrument. The 5 systems were labeled as a, b, c, d and e randomly.Results:Within the 5 systems, all values of blank check were less than 1.00 mg/L, the carryovers were lower than 1.00%. The repeatability of different ranges of CRP concentrations including 3.00-10.00, 10.00-30.00 and>30.00 mg/L were less than 10.00%, 6.00% and 5.00%, respectively, and the intermediate precision was less than 10.00%. The linearity correlation coefficients of the 5 systems were all above 0.975, while the slope was within 0.950-1.050. Whole blood samples were stable within 72 hours both at room temperature (18-25 ℃) and refrigerated temperature (2-8 ℃). The CRP results were rarely influenced by high triglyceride or bilirubin, except for the immmunoturbidimetric test based on microparticles coated with anti-human CRP F(ab) 2 fragments. When triglyceride was less than 15.46 mmol/L, the deviation of CRP was less than 10.00%. When bilirubin was less than 345.47 μmol/L, the deviation of CRP was less than 10.00%. CRP was more susceptible to Hct on the systems without Hct correction. The deviation of CRP between different Hct dilution concentration and 40% dilution concentration can reach as high as 67.48%. The correlation coefficients ( r) of 5 systems were all more than 0.975 in the range of 0-300.00 mg/L compared with Siemens specific protein analyzer. All systems passed the trueness verification using the samples with specified values of 12.89 and 30.60 mg/L. Conclusion:The performance of 5 systems can basically meet the clinical needs, but it is suggested that the whole blood CRP detection system without automatic Hct correction should be modified manually.

3.
Chinese Journal of Clinical Laboratory Science ; (12): 405-408, 2017.
Artigo em Chinês | WPRIM | ID: wpr-613346

RESUMO

Objective To design a POCT quality management system based on the Internet of things so as to standardize POCT quality management.Methods The existing problems in POCT quality management were analyzed.Taking portable blood glucose meters as an example,the quality management system of POCT-Internet of things was designed based on the all aspects of data acquisition,transmission,server management and storage,etc.Results The POCT quality management system based on the Internet of things and medical cloud technology was designed.The system could implement the management of POCT operators and devices,monitor the realtime quality control data and reports,and facilitate the administrators to analyze the quality problems in the whole process of POCT management.Conclusion The designed POCT quality management system based on the Internet of things has the theory feasibility.

4.
Chinese Circulation Journal ; (12): 50-53, 2017.
Artigo em Chinês | WPRIM | ID: wpr-508040

RESUMO

Objective:To explore the value of two-dimensional speckle tracking echocardiographic imaging (2D-STI) for assessing partial and global left ventricular functional changes at pre-and post-percutaneous coronary intervention (PCI) in patients with chronic total coronary occlusion. Methods:Echocardiograph was conducted in 23 chronic total coronary occlusion patients at pre-PCI and 1 day, 3, 6 months post-PCI to examine left ventricular ejection fraction (LVEF), meanwhile 2D-STI was applied to obtain the global longitudinal strain (GLS) value of left ventricle. Results:In all 23 patients, for LVEF, compared with pre-PCI (59.29±12.15)%, it was increased at 3 and 6 months post-PCI (60.00±12.35)%and (61.37±11.8)%respectively, all P Conclusion:PCI could effectively improve left ventricular function in patients with chronic total coronary occlusion, 2D-STI technology may quantitatively assess those changes at the early stage.

5.
International Journal of Laboratory Medicine ; (12): 1841-1843, 2015.
Artigo em Chinês | WPRIM | ID: wpr-473950

RESUMO

Objective To evaluate the performance of high-fluorescence body fluid cell (HF-BF)mode on the platform Sysmex XE-5000 automated blood analyzer,and analyse its clinical application value in diagnosis of meningeal carcinomatosis.Methods E-valuated the performance of HF-BF by using precision test and methodology comparison test.Retrospectively analyzed 295 test re-sults of cerebrospinal fluid in Zhongshan Hospital Affiliated to Xiamen University from June 2010 to September 2012.Results HF-BF on the platform Sysmex XE-5000 automated blood analyzer had high precision,and exhibited a good consistency with cytolgical examination.The percentage of high-fluorescence body fluid cell(HF-BF%)in the meningeal carcinomatosis group was higher than that in other cerebral diseases groups,had statistically significant differences (P < 0.05 ).The cut-off value for HF-BF% was 4.3%,while the area under a receiver operating characteristic (ROC)curve (AUC)was 0.933,the sensitivity was 95.2%,and the specificity was 92.7%.When HF-BF% was over 4.3%,it was more likely to detect tumor cell in cerebrospinal fluid cytology.Con-clusion HF-BF is an effective reference index for the early diagnosis of meningeal carcinomatosis and has significant clinical appli-cation value.

6.
Chinese Journal of Geriatrics ; (12): 454-457, 2012.
Artigo em Chinês | WPRIM | ID: wpr-426473

RESUMO

Objective To compare the predicting values for Prognosis among Global Risk Classification (GRS),Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) score,the European System for Cardiac Operative Risk Evaluation (EuroSCORE) in patients who received stenting because of unprotected left main coronary artery (ULMCA) lesion.Methods Totally 105 successive elderly patients with ULMCA lesion who received stenting were divided into 2 groups:with and without main adverse cardiac events (MACE).The clinical and angiographic characteristics were analyzed and then compared among GRC,SYNTAX score and EuroSCORE.Results As compared with none MACE group,MACE group had higher EuroSCORE score (2.0±2.3 vs.6.5±2.9,t=8.18,P=0.002),and more trivessel disease and left main bifurcation lesion (x2 =8.96,6.96,P =0.011,P =0.008).High risk GRC showed more MACE than medium or low risk GRC [55.9% (19/34) vs.20.5%(9/44),7.4% (2/27),x2 =19.77,P=0.001].AUC(95%CI )of GRC,SYNTAX score and EuroSCORE were [0.821 (0.730-0.912),0.586(0.462-0.709) and 0.631 (0506-0.757)],respectively.Compared with SYNTAX score and EuroSCORE,GRC was superior in the MACE predicting value (Z=3.29,2.63,P<0.01 or P<0.05).

7.
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care ; (6)2006.
Artigo em Chinês | WPRIM | ID: wpr-528997

RESUMO

Objective: To study the mechanism and effect of Chinese medicine Yiqi Tongyang Huatan prescription(益气通阳化痰方,YQTYHT) on hyperlipidemia and atherosclerosis(AS).Methods: The rabbit′s model was established by feeding the food containing high cholesterol,and 32 rabbits were randomly divided into four groups(each n=8): normal group,model group,Huoxue Huayu prescription treatment group(活血化瘀方,HXHY group) and YQTYHT treatment group(YQTYHT group).Before the experiment,at the end of 6 th and 12 th weeks after the experiment,the following items were measured: blood lipids platelet aggregation rate,platelet adhesion rate,malondialdehyde(MDA),endothelin-1(ET-1),nitric oxide(NO),the ratio of the lipid plaque area and the thickness of the endothelial plaque.Results: After feeding the food containing high cholesterol,the blood lipids,platelet aggregation rate,platelet adhesion rate,MDA,ET1,the ratio of lipid plaque area and the thickness of plaque were elevated significantly,while serum NO3-/NO2-decreased significantly in model group.Compared with the model group,the blood lipids were lower in the two treatment groups,and the blood lipid regulating effect in YQTYHT group was significantly better than that in HXHY group.Platelet aggregation rate and platelet adhesion rate of YQTYHT group and HXHY group were lower than those in the model group,but the degree of lowering in YQTYHT group and HXHY group had no significant differences.The serum MDA of YQTYHT group and HXHY group was lower than that in model group,and the lowering effect in YQTYHT group was better than that in HXHY group.YQTYHT group and HXHY group had a significant increase on the level of serum NO3-/NO2-and a decrease on the content of plasma ET-1,furthermore,the effects in the former group were significantly better than those of the latter group.The area of atherosclerotic plaque coverage in aorta and the thickness of plaque of HXHY group were larger than those in YQTYHT group(both P

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA